This is consistent with ANSI/AAMI HE 75 which recommends that “side rails, arm rests, leg supports . . . should be positioned, or able to be moved out of the way, so as not to interfere...
Search Results "Horizontal Position"
Commonly Searched Documents
-
Transfer Sides (M301.2.3 and M302.2.3)
-
Transfer Surface Height (M301.2.1 and M302.2.1)
Where patient support surfaces are contoured or upholstered for patient comfort or to support patient positioning during diagnostic procedures, the height of the transfer surface measured...
-
4.1.1 Range of Examination Table and Chair Configurations
would have to meet the technical criteria for each position supported....
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304....
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
5.6.1 Stirrups Provision for M301
5.6.1 Stirrups Provision for M301 NPRM Description: For patients with limited leg strength and control, thigh, knee and calf supports are necessary to maintain an appropriate position...
-
Position: ADA Standard Section 305.5
Section 305.5 covers the current ADA Standards for the positioning of clear floor and ground space.
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical and horizontal...
-
§ 35.150(b)(2)(ii)(K) Shooting facilities with firing positions
(K) Shooting facilities with firing positions, sections 243 and 1010....
-
M305.2.2 Length (Section-by-Section Analysis)
extend horizontally along the transfer surface to within three inches, to allow for manufacturing tolerances....
-
Standing Supports (M304.3 and M305.3)
M305.3 also provides technical criteria for standing supports in horizontal and vertical positions....
-
Audible Indicators: ADA Standard Section 407.4.8.2
Section 407.4.8.2 covers the current ADA Standards for audible elevator car indicators.
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
M305.2.3 Fittings
requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within their fittings, when in the use or latched position...
-
Lines of Sight for Wheelchair Spaces
Spaces must be dispersed horizontally and vertically. Horizontal dispersion pertains to the lateral, or side to side, location of spaces relative to the ends of rows....
-
M304 Diagnostic Equipment Used by Patients in Standing Position
[See subsections ...]
-
M304 Diagnostic Equipment Used by Patients in Standing Position
[See subsections ...]
-
1. Transfer Surface
[See subsections ...]
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
position and balance on diagnostic equipment used by patients in a standing position....
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs....