In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing...
Search Results "Head Height"
Commonly Searched Documents
-
606.3 Height
-
(3) Adjustability: Transfer Surface Intermediate Heights
low transfer height and a minimum high transfer height....
-
Protruding Objects
One element of a barrier-free meeting space for participants who are blind or have low vision requires cane-detectable protruding objects and sufficient head clearance....
-
606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing...
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
- Figure 605.2 Height and Depth of Urinals – Drawing from the U.S. Access Board
- Figure 703.2.5 Height of Raised Characters – Drawing from the U.S. Access Board
-
E2-c
Are any interior stairs along these routes configured with a cane-detectable warning or a barrier that prevents travel into the area with less than an 80-inch high head clearance so that...
- Figure 1009.2.4 Pool Lift Seat Height – Drawing from the U.S. Access Board
-
3.3.5 Seat Height
Comparisons of research findings on the seat heights for power chairs and scooters showed that mean seat heights measured in the UDI study were comparable to seat heights for the power chairs...
-
4.16.3* Height
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
4.16.3* HEIGHT
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
Seat Height [4.16.3]
Seat Height [4.16.3] Height preferences vary among people with disabilities....
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 2
- Pressalit Care Adult changing table 3000, electrically height adjustable 3D CAD Model
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 1
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
Counter Surface Height
Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....
- Delta Palm Hand Shower Head - Model 53001-DS