The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
Search Results "Fire Tower"
Commonly Searched Documents
-
[F] 907.4.2.2 Height
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Public and Common Use Areas: ADA Standard Section 215.2
Section 215.2 covers scoping requirements in the current ADA Standards for fire alarm systems in public and common use areas.
-
11B-215 Fire alarm systems and carbon monoxide alarm systems
[2010 ADA Standards] 215 Fire Alarm Systems ETA Editor’s Note The CBC includes carbon monoxide alarm systems. Therefore, the CBC is more inclusive....
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
-
809.5.1 Building Fire Alarm System
809.5.1 Building Fire Alarm System....
-
Transient Lodging: ADA Standard Section 215.4
Section 215.4 covers scoping requirements in the current ADA Standards for fire alarm systems in transient lodging.
-
Fire Rings, Grills, Fireplaces, and Woodstoves [1011.2, 1011.3, and 1011.5]
The usable sides of these elements are the sides that can be used for building a fire or for cooking....
- Pilot Rock Campfire Rings
- Pilot Rock FSW Series Accessible Campfire Ring
- Pilot Rock Campfire Ring Test
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
- Activar JL Industries 1900 Series Dual AED & Emergency Oxygen Recessed or Surface-Mounted Cabinet
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
- Pilot Rock FSW-30 Campfire Ring
- Pilot Rock FSW-26/18 Campfire Ring
-
F243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with 1010....
-
243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with 1010....
-
Shooting Facilities
Shooting Facilities If facilities provide fixed firing positions, at least 5 percent, but not less than one of each type of fixed firing position must be served by an accessible route...
- Pilot Rock FSWDW-30 Campfire Ring