These bases must go under, or fit around, the exam table in order to accomplish the transfer....
Search Results "Exam Chair"
-
Portable Floor Lifts
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
it is not feasible or possible to use a lift, another option is an adjustable-height stretcher or gurney (a table that is on wheels) that can be raised or lowered to the height of the exam...
-
4.1 Examination Tables and Chairs
4.1 Examination Tables and Chairs...
-
4.1.1 Range of Examination Table and Chair Configurations
4.1.1 Range of Examination Table and Chair Configurations Examination tables and chairs are used wherever patients are examined throughout the health care delivery system....
-
4.1.3 Adjustable Height Chairs with and without Footplates
4.1.3 Adjustable Height Chairs with and without Footplates Patients seated in adjustable height examination chairs typically rest their feet on the floor or on a footplate or have their...
-
5.1 Transfer Surface Height Recommendations
This height is also critical for patients who use mobility aids such as walkers and canes and may find it difficult to get up onto or down from an examination chair or table or imaging bed...
-
5.2.2 Transfer Surface Size Recommendations for M302
Depending on the configuration of the equipment, the transfer surface may coincide with the seat area of an examination chair....
-
5.2.2.1 Transfer Surface Width Recommendations for M302
5.2.2.1 Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily...
-
5.2.2.2 Transfer Surface Depth Recommendation for M302
5.2.2.2 Transfer Surface Depth Recommendation for M302 The Committee recommends a minimum depth requirement of 17 inches for equipment used by patients in seated...
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302 Description: The transfer surface size standard has two components: width and depth. The transfer surface...
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M301.2.3 and M302.2.3 Transfer Sides....
-
5.3.3 Transfer Sides Recommendations for M302
This provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M302.2.3 Transfer Sides....
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests Some examination chairs have footrests that get in the way of entry from the foot end, such as dental chairs...
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations
-
5.4.1 Transfer Support Location for M301 and M302
5.4.1 Transfer Support Location for M301 and M302 Description: Transfer supports assist individuals while making transfers on to the transfer area. Provisions require transfer...
-
5.4.2 Transfer Support Length for M301 and M302
5.4.2 Transfer Support Length for M301 and M302 Description: Transfer support length applies to the gripping surface of the support, that portion of the support used to grasp or...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the...
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and...
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent...