These push buttons are typically used as “request to exit” devices in access control applications. They can be installed in a single‐gang electric box or can be mullion mounted....
Search Results "Enclosed Exit Stairway"
- Door King Inc. 'Push to Exit' Button
-
1028.5 Access to a public way
The exit discharge shall provide a direct and unobstructed access to a public way....
-
SECTION 1009 STAIRWAYS
SECTION 1009 STAIRWAYS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
11B-504.3 Open risers
Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
11B-504.3 Open risers
Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
1009.11 Instructions
Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. 2....
-
11B-504.8 Floor identification
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
4.3.11.3* Stairway Width
Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails....
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
11B-504.8 Floor identification
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
11B-504.8 Floor identification
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
210 Stairways
210 Stairways...
-
R216 Stairways and Escalators.
R216 Stairways and Escalators....
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
Open Risers: ADA Standard Section 504.3
Section 504.3 covers the current ADA Standards for open risers on stairways.
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
They must provide direct access to an exit stairway (or to an elevator equipped with standby power). Horizontal exits can substitute for areas of refuge....
-
Exit Discharge [IBC §1023 (2003), §1006 (2000)]
Exit Discharge Steep terrain and other constraints can make it difficult to provide an accessible means of egress from building exits to a public way....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....