For those movie theaters that elect to meet these requirements through the exhibition of movies with open captioning, in whole or in part, the movie theaters may elect to turn on the open...
Search Results "Door Opening Angle"
-
Open Captioning (or Other Technologies) as an Option for Compliance (Section-by-Section Analysis)
-
R408.3 Open Risers
R408.3 Open Risers. Open risers are not permitted....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: 1....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: 1. ...
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
Manual Doors and Gates [§404.2]
Manual Doors and Gates [§404.2]...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Type: ADA Standard Section 407.3.1
Section 407.3.1 covers the current ADA Standards for elevator door type.
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with this section and Section 11B-809.8....
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
Angled Van Spaces
However, where van spaces are angled, an access aisle is required for each space on the passenger side (§502.3.4)....
-
Section 36.303(g)(1) Open Movie Captioning
“Open Movie Captioning” The NPRM proposed defining “open movie captioning” as “the provision of the written text of the movie dialogue and other sounds or sound making in an on-screen...
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
OPEN RISER
OPEN RISER. The space between two adjacent stair treads not closed by a riser....
- Access Board: Door Opening Force