When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
Search Results "Cane Detectable"
Commonly Searched Documents
-
11B-705.1.2.6 Reflecting pools
-
Dome Spacing: ADA Standard Section 705.1.2
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Dome Size: ADA Standard Section 705.1.1
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
Accessible Routes Throughout the Museum
Some people who are blind or have low vision use canes to detect barriers that jut into the path of travel, whether along the accessible route or any other circulation path....
-
2.11 Perceived Color of Detectable Warnings
The ability of people with visual impairments to correctly recognize the color of detectable warnings has important implications for both conspicuity and the potential for detectable warning...
-
4.29.4 Detectable Warnings at Stairs
4.29.4 Detectable Warnings at Stairs. (Reserved)....
-
Detectable Warnings on Walking Surfaces [4.29.2]
Detectable Warnings on Walking Surfaces [4.29.2] Detectable warnings are intended to alert pedestrians of an imminent hazard but are not designed as wayfinding devices....
-
Detectable Warnings at Stairs [4.9.5]
A requirement for detectable warnings has not been specified because of lack of data regarding effectiveness....
- Armor-Tile Tactile Systems Detectable Directional System
-
Detectable Warnings
Rail platform requirements include specifications for detectable warnings along platform boarding edges not protected by screens or guards (810.5.2)....
-
Sec.36.407 Temporary suspension of certain detectable warning requirements
Sec.36.407 Temporary suspension of certain detectable warning requirements....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
810.5.2 Detectable Warnings
810.5.2 Detectable Warnings....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
705 Detectable Warnings
[See subsections ...]
-
705 Detectable Warnings
[See subsections ...]
-
4.29 Detectable Warnings
[See subsections ...]
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-705.2 Detectable directional texture
11B-705.2 Detectable directional texture....
-
810.5.2 Detectable Warnings
Platform boarding edges not protected by platform screens or guards shall have detectable warnings complying with 705 along the full length of the public use area of the platform....
-
Durability and Maintenance of Detectable Warning Surfaces (Section-by-Section Analysis)
durability and maintenance of detectable warning surfaces....
-
A4.29.2 Detectable Warnings on Walking Surfaces
A4.29.2 Detectable Warnings on Walking Surfaces. The material used to provide contrast should contrast by at least 70%....
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm), with bars...
-
11B-705.1 Detectable warnings
[See subsections ...]