(1) Elements such as ramps, elevators or other vertical circulation devices, ticketing areas, security checkpoints, or passenger waiting areas shall be placed to minimize the distance which...
Search Results "Ramp Run"
Commonly Searched Documents
-
10.4.1(1)
-
A. Passenger Drop-Off Areas
Curb ramp connects the access aisle for the accessible drop-off area (which is at the level of the parking lot) to the accessible route to the accessible entrance of the shelter....
-
11B-502.4 Floor or ground surfaces
Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48. ◼ Advisory 11B-502.4 Floor or ground surfaces...
-
505.7.2 Non-Circular Cross Sections
505.7.2 Non-Circular Cross Sections. Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm)...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section...
-
E. Services in the Cabin
Within the aircraft cabin, when requested by a passenger with a disability or when offered and accepted by a passenger with a disability, you must assist the passenger...
-
Except in an Emergency Evacuation, No Hand-Carrying Passengers
Except in an Emergency Evacuation, No Hand-Carrying Passengers Under no circumstances – except for emergency evacuations – should you physically pick up a passenger with a...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section...
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Non-Circular Cross Section and Clearance (§505.5, §505.7)
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section...
-
4.2 Physical Accessibility Barriers and Solutions
temporary signs to mark additional parking spaces Restripe parking area to include ADAAG required widths for accessible parking spaces No curb cuts Install a temporary ramp...
- Design Guidelines for the Visual Environment
-
5. Edge Protection
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
§ 382.40 Boarding assistance for small aircraft
(b) Carriers shall, in cooperation with the airports they serve, provide boarding assistance to individuals with disabilities using mechanical lifts, ramps, or other suitable devices that...
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
Exceptions: In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted...
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
The exception to the minimum width in M303.2.2 would apply where ramped surfaces are provided on the opposite sides of the raised platform so that patients using wheelchairs can enter and...