* Many FM transmitters are capable of being adjusted to provide a range of preprocessing possibilities....
Search Results "Dimension Range"
-
2.2.4 Issues
-
4.3.4 Knee and Toe Clearances
The following dimensions on knee and toe clearances should be used to accommodate 95% of our study sample on all four dimensions: • Toe clearance depth: 127 mm (5 in.) maximum, measured...
-
Combination Wheelchair/Horse Accessible Gates
The gate dimensions work well together because the required turning diameter for a wheelchair is 60 inches....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
Clear Floor Space [4.35.2]
Recommendations: Consider additional space on the narrow dimension to allow alternative transfers. Some people may need to fully recline to dress or change clothes....
-
4.21.2 Size and Clearances
Institutional showers exceeded the minimum stall dimensions....
-
11B-703.7.2.1 International Symbol of Accessibility
A border may be provided inside or outside of the minimum required International Symbol of Accessibility dimension. [2010 ADAS] 703.7.2.1 International Symbol of Accessibility....
-
11B-812.10.4 Location
Where the long dimension of a vehicle space is parallel to the vehicular way, the EV charger shall be adjacent to, and 48 inches (1219 mm) maximum from the head end or foot end of the vehicle...
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
Caution regarding minimum Aisle Widths for aisles that serve "elements on both sides"
of an aisle in, say, a Mercantile Group M Occupancy, vs. what we have understood it to mean: the clear width related to egress when a Main Aisle is fed by feeder aisles (also known as 'Range...
-
4.3.1 Reference WhMD Users
The Reference Users should include plan and elevation drawings and have key dimensions coded with a corresponding table of values for each code showing the 5th, 25th, 50th, 75th and 95th...
-
702 Fire Alarm Systems
In the proposed rule, the Board sought comment on whether the frequency of audible alarms should be addressed and requested information on the optimal frequency range for people who are...
-
4.5 Weight Scales
An accessible weight scale that can accommodate a wide range of patient populations and mobility devices solves that problem....
-
Telescopes and Periscopes
Telescopes and periscopes that are usable from a seated position will provide the widest range of viewing opportunities for seated individuals, as well as children and people of short stature...
-
Components (M303.4)
The proposed height range for the breast platform is based on the above anthropometric data....
-
228 Depositories, Vending Machines, Change Machines, and Mail Boxes
Gas pump manufacturers expressed concerns about reach range requirements and operating force specifications which have been addressed in the final rule, as discussed in sections 308 and...
-
M303.4.1 Breast Platform Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a mammography breast platform height range of 30 inches high minimum and 42 inches high maximum above the floor....
-
Chapter 6 BUILDING AN EVACUATION PLAN FOR A PERSON WITH A COGNITIVE DISABILITY
These disabilities are caused by a wide range of conditions, but all result in some decreased level of ability to process or understand information or situations....
-
11B-411.2.1.6 Identification of floors served
provided with signage complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface of or above the hall call console stating “FLOORS n1 – n2”, where n1 - n2 represents the range...
-
11B-411.2.1.6 Identification of floors served
provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface of or above the hall call console stating “FLOORS n1 – n2”, where n1 - n2 represents the range...
-
11B-411.2.1.6 Identification of floors served
provided with signs complying with Sections 11B-703.2, 11B-703.3, and 11B-703.5 on the surface of or above the hall call console stating “FLOORS n1 – n2”, where n1 - n2 represents the range...
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
- Structure Sensor 3D Depth Scanning Software for 3D Imaging and Printing
-
502.3.3 Values (Section-by-Section Analysis)
502.3.3 Values (Section-by-Section Analysis) This section proposes that current values, as well as any set or range of allowable values associated with a programming object, must be programmatically...