We believe the addition of the adjustability requirement delivers by far a larger increase in access than having a single minimum height of 17 inches....
Search Results "Adjustable Height Counter"
Commonly Searched Documents
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. ...
-
5.8.2.5 Toe Height Recommendation
recommended that the toe height be set to 18 inches (when the breast platform is at the 34 inch height discussed above)....
-
5.8.3.1 Breast Platform Height
5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
SEAT HEIGHT MEASUREMENT DETAIL
SEAT HEIGHT MEASUREMENT DETAIL Regardless of measurement technique used, the height is measured at the highest point of the seat, inclusive of bolsters, with the foam in an uncompressed...
-
M303.2.4.2.2 Height
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Protocol C Heights Obtained
For the maximum height transfers HERL's percentile heights were slightly higher for the 25th and 75th percentiles than the NDVWSC heights....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
-
Check Height and Location of the Pushbutton
Check Height and Location of the Pushbutton Confirm that pushbutton height and location conform to specifications and can be reached by a person in a wheelchair, from a hard surfaced level...
-
Table 2: Summary of Department of Transportation Survey
±1" (±25 mm) None for handrail height. 17 Street furniture–horiz. placement 1 in. 12 in. 3.27 in....
- Bradley Adjustable Tilt Mirror 782
-
Protocol B Heights Obtained
Again for the minimum height protocol HERL participants transferred lower on average than the NDVWSC participants....
-
11B-611.4 Height
11B-611.4 Height. Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- Access Board: Signs
-
11B-611.4 Height