5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
Search Results "Residential Structure"
-
1132A.3, Item 5
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.7 Accessible routes
An accessible route shall be provided complying with Section 11B-809.7. The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
Issue: Historically Significant Facilities
Structural changes to these facilities that would threaten or destroy the historical significance of the property or would fundamentally change the program being offered at the historic...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
608.4 Seats (Exception)
An exception to the section permits seats to not be installed in transfer type shower compartments in residential dwelling units required to provide mobility features provided that the walls...
-
1.1.3.2 State-regulated buildings, structures, and applications
Buildings or structures used or intended for use as an: 1. Asylum, jail, prison 2....
-
UNREASONABLE HARDSHIP
The second type applies to alterations, structural repairs, or additions that do not exceed a valuation threshold specified in Section 11B.202.4, Exception 8....
-
F206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
- Structure Sensor At Ripley's Believe It Or Not
-
Alterations
Technically infeasible means: “… something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member...