Search Results "Patient Toilet Room"
Commonly Searched Documents
-
806 Transient Lodging Guest Rooms
-
11B-241 Saunas and steam rooms.
[See subsections ...]
-
11B-241 Saunas and steam rooms
[See subsections ...]
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56798
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56783
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
General: ADA Standard Section 806.1
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
- Georgia-Pacific Compact® Brushed Steel Finish Side-By-Side Double Roll Bathroom Tissue Dispenser 56796
- AJW Architectural Products U683 Dual Stall Toilet Tissue Dispenser & Sanitary Napkin Disposal - Partition Mounted
-
11B-806.1 General
Transient lodging guest rooms shall comply with Section 11B-806. Guest rooms required to provide mobility features shall comply with Section 11B-806.2....
-
Saunas and Steam Rooms
Saunas and Steam Rooms If saunas or steam rooms are in a cluster, at least 5 percent, but not less than one of each type must be accessible....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
-
I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use an exam table that is not accessible?
Q I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use...
-
11B-216.1 General
The substantive difference between the CBC and 2010 ADAS scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational signs...
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table
-
M305.5 Head and Back Support (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients in the supine, prone, or side-lying position and the seated position that can be adjusted to a reclined position to...
-
4.4.2 Head Room
Walks, halls, corridors, passageways, aisles, or other circulation spaces shall have 80 in (2030 mm) minimum clear head room (see Fig. 8(a))....
-
4.4.2 HEAD ROOM
Walks, halls, corridors, passageways, aisles, or other circulation spaces shall have 80 in (2030 mm) minimum clear head room (see Fig. 8(a))....
-
Saunas and steam rooms. (Section-by-Section Analysis)
The Department is proposing one specific provision to minimize the potential impact of the new requirements on existing saunas and steam rooms. ...
-
604.7 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
604.7 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
604.7 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4]
Where pictograms are used to label "permanent" rooms and spaces (e.g., restrooms), the verbal equivalent must be provided in raised and Braille characters....