Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
Search Results "Hoistway Clearance"
-
General: ADA Standard Section 404.1
-
11B-809.10.6.3 Clearance
A clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided outside the shower as illustrated in Figure 11B-809.10.6.3...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Features of an Accessible Examination Room
Maneuvering clearances are needed at the door to the room. Note: Additional clear floor space can be provided by moving or relocating chairs, trash cans, carts, and other items....
-
Size and Clearances for Shower Compartments: ADA Standard Section 608.2
Section 608.2 covers the current ADA Standards for the size and clearances of shower compartments.
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory...
-
608.2.2.1 Clearance
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
Advisory 1003.3.2 Boarding Pier Clearances. These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
603.2 Clearances
603.2 Clearances. Clearances shall comply with 603.2....
-
1002.4.4 Clearances
1002.4.4 Clearances. Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1....
-
403.5 Clearances
403.5 Clearances. Walking surfaces shall provide clearances complying with 403.5....
-
604.9.2 Clearance
604.9.2 Clearance. Clearance around a water closet shall comply with 604.3....
-
604.3 Clearance
604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3....
-
General: ADA Standard Section 306.1
Section 306.1 of the ADA Standards covers information in the current ADA Standards for knee and toe clearance.
-
Handrails [§405.8, §505]
Handrail Height and Clearance Handrail Continuity and Extensions Surface requirements and clearances facilitate a power grip along the length of handrails....
-
Clearances [§403.5]
Clearances [§403.5] The minimum 36” continuous clear width of accessible routes can reduce to 32” at points, such as doorways, for a maximum distance of 24”....
-
(1)(c)
(c) A grab bar at least 24 inches (610 mm) long should be mounted behind the water closet, and a horizontal grab bar at least 40 inches (1015 mm) long should be mounted on at least...
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with...