(b) Reach Depth More Than 10 in (255 mm). Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed...
Search Results "Parallel Curb Ramp"
Commonly Searched Documents
-
4.34.3(2)(b) Reach Depth More Than 10 in
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
(a) Reach Depth Not More Than 10 in (255 mm). Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the...
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space can be oriented for a side approach instead of a forward approach at most operable parts. Nominal centering of the space on operable...
-
4.1.2(5)
EXCEPTION: Accessible ramps complying with 4.8 or, if no other alternative is feasible, accessible platform lifts complying with 4.11 may be used in lieu of an elevator....
- Simplified Building Concepts: ADA - Building an Upright
- Simplified Building Concepts: Assembling the ADA Railing
- Simplified Building Concepts: ADA - Message to Contractors
- Simplified Building Kee Access ADA Railings
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
Cross Slope and Surfaces [4.8.6]
Ramp surfaces must comply with requirements for ground and floor surfaces and be "stable, firm, and slip-resistant." A specific level of slip-resistance is not mandated....
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces....
-
11B-406.2.2 Sides of curb ramps
Where provided, curb ramp flares shall not be steeper than 1:10. FIGURE 11B-406.2.2 ‡‡ SIDES OF CURB RAMPS...
- citEcar ADA Electric Shuttle 11P 1WC
- citEcar ADA Enclosed Shuttle 11P 1WC
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the platform...
-
Problem Three (Accessible Route)
Solution: Install a portable ramp....
-
502.2 Vehicle Spaces
See section 406.5 curb ramp location....
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings.
-
505.9 Fittings