Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.
Search Results "Clearance"
Commonly Searched Documents
-
General: ADA Standard Section 410.1
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
Clear Deck Space: ADA Standard Section 1009.4.1
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Do drinking fountains pose hazards as protruding objects?
This is not required for wheelchair accessible units with no more than a 27” clearance below (the minimum required for knee clearance and the maximum recognized for cane detection)....
-
Introduction
Introduction This memo provides a revised description and analyses examining knee clearance dimensions in mammography equipment (as requested in your email dated: 4/15/2013)....
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
Doors: ADA Standard Section 604.8.2.2
Section 604.8.2.2 covers the current ADA Standards for ambulatory accessible compartment doors.
-
1133B.2.4.2
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
A4.6.3 PARKING SPACES
High-top vans, which disabled people or transportation services often use, require higher clearances in parking garages than automobiles....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
Recessed Lavatories
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
-
References:
“Clearance Space Envelopes of Wheeled Mobility Device Users for Computer Workstations”. Proceedings of the Human Factors and Ergonomics Society Annual Meeting 2012....
-
Conclusions
Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...