Clear spaces shall be 760 mm (2.5 ft) minimum by 1220 mm (4.0 ft) minimum....
Search Results "Water Closet Clear Floor Space"
-
R404.3 Size
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
- Access Board: Clear Floor Space Position
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space....
-
Location
As Gregory Scott, AIA, partner in RLPS, responded: "…the major challenge with the implementation of ADAAG, is not with excessive space requirements or even required clearances; but more...
-
Bathroom Design Illustrations
However, the second set of specifications provides for a clear access aisle adjacent to the tub that would permit a parallel approach to the tub....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
4.22.3 CLEAR FLOOR SPACE
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room....
-
Sec.36.304(b)(12)
(12) Installing grab bars in toilet stalls;
-
§ 36.304(b)(12)
(12) Installing grab bars in toilet stalls;
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners....
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and that...