By June Isaacson Kailes, Associate Director Center for Disability Issues and the Health Professions Western University of Health Sciences jik@pacbell.net 2008...
Search Results "Patient Room"
-
5 “G’s” Getting Access to Health Care for People with Physical Disabilities
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows....
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows....
-
806.2.4 Toilet and Bathing Facilities
At least one bathroom that is provided as part of a guest room shall comply with 603....
-
806.2.4 Toilet and Bathing Facilities
At least one bathroom that is provided as part of a guest room shall comply with 603....
-
Doorways
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2)....
-
806.2.4 Toilet and Bathing Facilities
At least one bathroom that is provided as part of a guest room shall comply with 603....
-
Dispersion: ADA Standard Section 224.5
Section 224.5 covers scoping requirements in the current ADA Standards for dispersion of transient lodging guest rooms.
-
11B-224.5 Dispersion
Guest rooms required to provide mobility features complying with Section 11B-806.2 and guest rooms required to provide communication features complying with Section 11B-806.3 shall be dispersed...
-
11B-224.5 Dispersion
Guest rooms required to provide mobility features complying with Section 11B-806.2 and guest rooms required to provide communication features complying with Section 11B-806.3 shall be dispersed...
-
Orienting Attendees to the Meeting Space
their relation to each other, for example – or information on a smaller scale, such as the location of the coffee pot, telephone, toiletry products, and thermostat in a hotel sleeping room...
-
5.8.2.4 Unobstructed Floor Space Recommendation
During a mammography procedure, the patient’s chest is flush with the front edge of the breast platform and the technician positions the patient’s breast on the breast platform....
-
11B-806.2.4 Toilet and bathing facilities
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603....
-
11B-806.2.4 Toilet and bathing facilities
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603....
-
11B-806.2.4 Toilet and bathing facilities
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603....
-
M301.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A. A low transfer position...
-
M301.2.2 Sunset
The low transfer position height, Item A of M301.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register].
-
M301.2.2 Sunset Provision (Section-by-Section Analysis)
As discussed in Section IV.B.1.a. (Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new...
-
Knee and Toe Clearance (M303.2.4)
Knee and toe clearance are critical where patients seated in a wheelchair need to position their knees and toes next to or underneath a component of the diagnostic equipment....
-
F206.7.6 Guest Rooms and Residential Dwelling Units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...
-
206.7.6 Guest Rooms and Residential Dwelling Units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...
-
Transient Lodging: ADA Standard Section 215.4
Section 215.4 covers scoping requirements in the current ADA Standards for fire alarm systems in transient lodging.
-
J. Bedside Clearance
________ ... is there clear passage at the foot of each bed that is at least 36" wide so that persons who use wheelchairs can approach and use the accessible features throughout the room...
-
4.35.4 Bench
Every accessible dressing room shall have a 24 in by 48 in (610 mm by 1220 mm) bench fixed to the wall along the longer dimension....