In residential dwelling units with mobility features where receptacles are provided in a kitchen at a corner work surface, one receptacle shall be located 36 inches (915 mm) from either...
Search Results "Multistory Dwelling Unit (FHA)"
-
11B-205.1 General
-
11B-205.1 General
In residential dwelling units with mobility features where receptacles are provided in a kitchen at a corner work surface, one receptacle shall be located 36 inches (915 mm) from either...
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide....
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide....
-
Emergency Transportable Housing: ADA Standard Section 3.
Emergency transportable housing units, which are designed and manufactured for transport over roadways, have a smaller footprint than other types of housing and pose unique accessibility...
-
F245.2.1 Picnic Facilities with Two or Fewer Picnic Units
Where picnic facilities contain two or fewer picnic units, each picnic unit shall provide mobility features complying with F245.2....
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide....
-
1012 Parking Spaces Within Camping Units and Picnic Units and Pull-Up Spaces at Dump Stations
[See subsections ...]
-
233.3.6 Dispersion (Exception 2), F233.3.5 Dispersion (Exception 2), F233.4.6 Dispersion (Exception 2)
Residential dwelling units required to provide mobility features complying with 809.2 and residential dwelling units required to provide communication features complying with 809.3 shall...
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following requirements....
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling units, at least one shower stall shall comply with one of the following requirements....
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
At least one of each type of element provided within picnic units with mobility features, including outdoor constructed features and parking spaces, must comply with the applicable technical...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
F245.2.2 Picnic Facilities with More Than Two Picnic Units
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility features complying with F245.2....
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work...
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space,...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.