In residential dwelling units required to provide mobility features complying with 809.2 through 809.4, all doors and doorways providing user passage shall comply with 404....
Search Results "Compartment Door"
Commonly Searched Documents
-
206.5.4 Residential Dwelling Units
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
D6. Vestibule Clear Floor Space
[ADA Stds 4.13.7] Yes _____ No _____ If No, leave the inner door open or remove inner door, add power operators to both doors so they open at the same time or, modify the vestibule...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
Hadrian Inc. Toilet Partition Floor Mounted Privacy Screens
Requires the Premium User plan or above. (Login or upgrade your account!)
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
- ADAEZ Pro Plus Automatic Door Opener Installation Video
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
Requirement 3 -- Usable Doors
[See subsections ...]
-
Guest Rooms
This applies to all doors, including bathroom doors that allow full user passage....
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
T502 Doorways
[See subsections ...]
-
§ 38.93 Doorways
[56 FR 45756, Sept. 6, 1991, as amended at 76 FR 57939, Sept. 19, 2011]
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309....
-
§ 38.113(c) Signals
If doors to the platform close automatically or from a remote location, auditory and visual warning signals shall be provided to alert passengers of closing doors...
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest room....