Search Results "Shower Grab Bar"
Commonly Searched Documents
- Figure 610.3.2 L-Shaped Shower Seat – Drawing from the U.S. Access Board
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...
-
11B-224.1.2 Guest room doors and doorways
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-224.1.2 Guest room doors and doorways
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-224.1.2 Guest room doors and doorways
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
Swanstone Barrier-Free Shower Floor FBF-3464
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Attachment E
The rear grab bar is too short. ...
- Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Proline Drain
-
610 Seats
[See subsections ...]
-
610 Seats
[See subsections ...]
-
610 Seats
610 Seats
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-206.5.3 Transient lodging facilities
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-206.5.3 Transient lodging facilities
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
4.34.5.5(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head at various heights or as a hand-held shower shall be provided....
-
4.34.5.4(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
1134A.8, Item 8
8. Mirrors and towel fixtures. Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor.
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails and Beach Access Routes
Federal agencies shall document the basis for not fully complying with a specific provision in 1017 or 1018 on a portion of a trail or beach access route based on Exception 1 in...
-
1018.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of a beach access route shall not be steeper than 1:10 (10%). Where the running slope of a segment of a beach access route is steeper than 1:20...
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided. The curbs or barriers...
-
1018.8.2 Slope
Resting intervals shall have a slope not steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than...
-
1018.1 General
Beach access routes shall comply with 1018. EXCEPTIONS: 1. When an entity determines that a condition in 1019 does not permit full compliance with a specific provision in 1018 on...
-
Running Slope [1018.7.1]
The running slope of any segment of a beach access route must be no steeper than 1:10 (10 percent). When the running slope of a segment of beach access route is steeper than 1:20...