Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
Search Results "Non-Elevator Building"
-
11B-407.4.6.1 Location
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Subpart F—Certification of State Laws or Local Building Codes (Section-by-Section Analysis)
For example, if a State agency that regulates buildings seeks certification of its building code, it should be able to do so, even if another State agency that regulates amusement rides...
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
Door and Signal Timing
This provision helps ensure that elevator doors remain open long enough for persons with disabilities to travel from call buttons to the responding car and is based on a travel speed of...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
General
Section 207.1 of the 2010 Standards reference the International Building Code (IBC) for scoping and technical requirements for accessible means of egress....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
Guidelines for Requirement 5
Electrical outlets installed to serve individual appliances, such as refrigerators or built-in microwave ovens, may be mounted in non-accessible locations....
-
4.3.2(2)
(2) At least one accessible route shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
4.1.1(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
4.1.2(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
T201.1 General
Non-rail vehicles purchased, leased or remanufactured by entities covered by the Americans with Disabilities Act (ADA) shall comply with the requirements in the Non-Rail Vehicle Guidelines...