F216.4.2 Areas of Refuge
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush.
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush.
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
T103 Definitions
These terms are: boarding platform, fixed route service (or fixed route), large transit entity, large non-rail vehicle, small non-rail vehicle, and non-rail vehicle....
-
Elevators and Platform Lifts
Elevators and Platform Lifts In addition to regular elevators, limited use/limited application elevators (smaller, slower elevators used for low-traffic, low-rise facilities) or platform...
-
216.4.2 Areas of Refuge
Signs required by section 1003.2.13.5.4 of the International Building Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference...
-
7. What is the difference between a “portable” lift and a “fixed” lift?
The real issue is not whether a lift is “portable” versus “fixed,” but rather whether a lift is “fixed” versus “non-fixed.”...
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
Is color contrast required for stair nosings?
treads is helpful for people with low vision, but it is not required by the Standards except at escalators in rail and fixed guideway stations which must meet the ASME A17.1 Safety Code for Elevators...
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding 2013 CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADAS....
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADAS....
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console. ...
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
4.1.6(1)(k)(ii)
For example, alterations to floors above or below the ground floor must be accessible regardless of whether the altered facility has an elevator....
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...