Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B 1991 Standards Plan-1A Pair: 1991 Standards with Out-Swinging Doors...
Search Results "Double Door"
Commonly Searched Documents
-
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- Besam SW200i Surface Mounted Swing Door Operator for Dual Egress
- Cal-Royal 300 Series Hydraulic Door Closers
- Besam SW200i Overhead Concealed Swing Door Operator for Dual Egress
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- Cal-Royal 900 Series Hydraulic Door Closers
- Mockett DH401-BB Slim Barrel Door Handle Back to Back
- Panda TS.60 Thermally Broken Folding Door System
- Hager Companies Round Offset Door Push/Pull Set 24Q
-
Features of an Accessible Examination Room
Accessible entry door has 32” minimum clear opening width with door open 90 degrees. 7. Maneuvering clearances are needed at the door to the room....
- Hager Companies 5100 Series - Heavy Duty Surface Door Closer
- Mockett DH5/BB Large Cylindrical Door Handle Back to back
- Mockett DH4/BB Slim Cylindrical Door Handle Back to back
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1013.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
- Norton Surface Mounted Light Duty 210 Series Door Closer
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
- Cal-Royal 700 Series Hydraulic Door Closers