Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
Search Results "Water Closet Centerline"
-
11B-812.1 General
-
11B-812.1 General
Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool....
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
Toilet and Bathing Rooms
However, the scoping at section 213.2.1 of the 2010 Standards coordinates with model plumbing and building code requirements which will permit a small toilet room with two water closets...
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool....
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the parking space...
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the vehicle space...
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
11B-809.2.1 Location
Where only one accessible route is provided, it shall not pass through bathrooms, closets, or similar spaces....
-
11B-809.2.1 Location
Where only one accessible route is provided, it shall not pass through bathrooms, closets, or similar spaces....
-
Location: ADA Standard Section 809.2.1
Where only one accessible route is provided, it shall not pass through bathrooms, closets, or similar spaces....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
Visible Signals: ADA Standard Section 407.2.2.2
Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
Accessible Lavatory
provisions in 213.3 for plumbed fixtures and accessories include: removing as unnecessary the distinction between toilet compartments and toilet rooms in scoping accessible water...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...