Search Results "Unisex Toilet Room"
Commonly Searched Documents
-
224 Transient Lodging Facilities and Guest Rooms
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
B. Clear Width
Do bathroom doors in all guestrooms allow 32" clear passage width so persons who use wheelchairs, crutches, and other mobility aids can visit or stay in other rooms and use the bathroom?...
-
Facilities Specializing in Treating Conditions That Affect Mobility: ADA Standard Section 223.2.2
Section 223.2.2 covers scoping requirements in the current ADA Standards for facilities specializing in treating conditions that affect mobility.
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
206.7.6 Guest Rooms and Residential Dwelling Units F206.7.6 Guest Rooms and Residential Dwelling Units The final rule edits the references in these sections to the technical requirements...
-
H17
Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No...
-
5.3.5 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1.
-
Size and Arrangement [4.17.3]
[See subsections ...]
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. The...
- Stanley Access Technologies Dura-Care 7000 Manual Door System
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
- Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door
- Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
-
Construction Sites (§203.2)
Construction Sites (§203.2) Structures directly associated with the actual processes of construction and portable toilets used only by construction workers Examples: scaffolding...
- Disability Access - Tips for the small business
-
Patient Bedrooms [6.3]
[See subsections ...]
-
6.3 Patient Bedrooms
Provide accessible patient bedrooms in compliance with 4.1 through 4.35. Accessible patient bedrooms shall comply with the following:
-
6.3 PATIENT BEDROOMS
Provide accessible patient bedrooms in compliance with 4. Accessible patient bedrooms shall comply with the following: