[See subsections ...]
Search Results "Residential Facility"
Commonly Searched Documents
- 
    
  
  11B-245 COMMERCIAL FACILITIES LOCATED IN PRIVATE RESIDENCES
  
 - 
    
  
  604.3.2 Overlap
  
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
 - 
    
  
  11B-809.10.3 Powder rooms
  
When the powder room is the only toilet facility located on an accessible level it shall, in addition, comply with Sections 11B-809.10.4, 11B-809.10.7 and 11B-809.10.8....
 - 
    
  
  11B-210.1 General
  
In detention and correctional facilities, stairs that are not located in public use areas shall not be required to comply with Section 11B-504. 2....
 - 
    
  
  11B-232.2 General holding cells and general housing cells
  
Many detention and correctional facilities are designed so that certain areas (e.g., "shift" areas) can be adapted to serve as different types of housing according to need....
 - 
    
  
  604.3.2 Overlap
  
[ECTCR UFAS 4.16.2, Fig. 28, 4.34.5.2(1), Fig. 47(a)] EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum...
 - 
    
  
  Accessible Cells in Correctional Facilities
  
Many inmates in State and local correctional facilities have mobility disabilities and need to be housed in accessible cells....
 - 
    
  
  101.2 Effect on Removal of Barriers in Existing Facilities
  
Removal of architectural barriers, pursuant to 28 C.F.R. s. 36.304, from buildings, structures or facilities shall comply with this code’s requirements for alterations unless compliance...
 - 
    
  
  § 36.402(b)(1)
  
maintenance, reroofing, painting or wallpapering, asbestos removal, or changes to mechanical and electrical systems are not alterations unless they affect the usability of the building or facility...
 - 
    
  
  Dispersion of Cells
  
The NPRM did not contain express language addressing dispersion of cells in a facility....
 - 
    
  
  11B-809.5.3 Interconnection
  
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
 - 
    
  
  §27.71 Airport facilities.
  
[61 FR 56424, Nov. 1, 1996, as amended at 68 FR 51391, Aug. 26, 2003; 78 FR 67917, Nov. 12, 2013; 80 FR 46513, Aug. 5, 2015]
 - 
    
  
  § 27.71 Airport facilities.
  
* * * * *
 - 
    
  
  Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way
  
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way The proposed guidelines are developed specifically for pedestrian facilities in the public...
 - 
    
  
  Sec.36.401(b) Commercial facilities located in private residences
  
(b) Commercial facilities located in private residences. ...
 - 
    
  
  Water Closet Clear Floor Space in Toilet Compartments
  
However, the Board has revised the specified depth in residential dwelling units where lavatories are permitted to overlap the space aside water closets....
 - 
    
  
  11B-809.4.1 Subsequent bathrooms
  
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
 - 
    
  
  11B-233.3.1.2.3 Ground floors above grade
  
Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable....
 - 
    
  
  Section 37.41 Construction of Transportation Facilities by Public Entities
  
Section 37.41 Construction of Transportation Facilities by Public Entities Section 37.41 contains the general requirement that all new facilities constructed after January 25, 1992, be...
 - 
    
  
  Section 36.406(d) Social Service Center Establishments (Section-by-Section Analysis)
  
To resolve these conflicts, the residential facilities standards in the 2004 ADAAG have been coordinated with the section 504 requirements....
 - 
    
  
  12147(a) General rule
  
(a) General rule With respect to alterations of an existing facility or part thereof used in the provision of designated public transportation services that affect or could affect the...
 - 
    
  
  11B-809.4.1 Subsequent bathrooms
  
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
 - 
    
  
  11B-809.4.1 Subsequent bathrooms
  
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
 - 
    
  
  §40.3(a)
  
(a) The standards prescribed in §40.4 are applicable to residential structures designed after the effective date of this part....