§100.10(a)(2)
-
4.1.7(2)(b)
EXCEPTION: If it is determined that no entrance used by the public can comply with 4.14, then access at any entrance not used by the general public but open (unlocked) with directional signs...
-
Certain Sports/ Recreation and Other Structures (§203.10 - §203.14)
solely for refereeing, judging, or scoring a sport raised boxing/ wrestling rings water slides and raised diving boards/ platforms animal containment areas not open...
-
Can van spaces required for a parking garage be located in a surface lot instead?
Open lots do not provide the same level of protection, security, and lighting as garage parking....
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
106.5.51 Public Way
Any street, alley or other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public...
-
Staff Training
Staff Training Ongoing staff training is essential to ensure that accessible equipment (particularly pool lifts) and pool facilities are available whenever a pool is open....
-
11B-804.6.2 Operable parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with Section 11B-309.3....
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
H6
[ADA Standards § 4.13.7] Yes No If No, possible solutions include leaving the inner door open or removing the outer door....
-
Head Room [4.4.2]
This is important at open stairways and along sloped walls....
-
Doors
Recommendation: Compliance with 4.13.6 is recommended because while wider door openings may facilitate access, they do not fully compensate for latch-side clearance, particularly on the...
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
§ 38.173(c)
(c) In stations where open platforms are not protected by platform screens, a suitable device or system shall be provided to prevent, deter or warn individuals from stepping off the platform...
-
11B-804.6.2 Operable parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with Section 11B-309.3....
-
Captioning
However, various technologies have been developed to provide open or closed captioning for movie theaters....
- Allegion Falcon 1490 Series Exit Devices
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
D6
[ADA Standards § 4.13.7] Yes No If No, leave the inner door permanently open, remove inner door, or modify the vestibule....
-
§ 36.311(a) Use of wheelchairs and manually-powered mobility aids
wheelchairs and manually-powered mobility aids, such as walkers, crutches, canes, braces, or other similar devices designed for use by individuals with mobility disabilities in any areas open...
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
Issues of Change
Issues of Change: Recognize that a change in the office environment, job tasks, or of supervisors may be difficult for a person with autism Maintain open channels of communication...
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Since spring and gravity hinges do not significantly impact the opening force of doors, they are not considered “closers” for purposes of specifying door maneuvering clearance....