If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
Search Results "Open Riser"
-
4.13.10* DOOR CLOSERS
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
1134A.6 Showers
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or 1.2. ...
-
11B-307.2 Protrusion limits
Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). ◼ ...
-
11B-307.2 Protrusion limits
Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). ◼ ...
-
406.2.2 Clear height
Exception: A lower clear height is permitted for a parking tier in mechanical-access open parking where approved by the building official. Advisory 406.2.2 Clear height....
-
Car Dimensions and Doors: ADA Standard Section 408.4.1
Section 408.4.1 covers the current ADA Standards for the car dimensions and doors of limited-use/limited-application elevators.
-
11B-809.8.3 Door maneuvering clearance.
A 39 inch (991 mm) minimum length is allowed at interior doors when a clear opening width of 34 inches (864 mm) minimum is provided....
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
382.113 What services are carriers not required to provide to passengers with a disability on board the aircraft?
Personal care services like assistance in actual eating and drinking are not required, but more limited assistance such as assisting with the opening of packages is required....
-
D3
[ADA Standards § 4.13.9] Yes No If No, leave door propped open, add new accessible hardware, or adapt/replace hardware. ...
-
1. Faucet Controls
Are the tub faucet controls positioned between the center of the end wall and the open side of the tub so persons with disabilities may approach and adjust the controls before they transfer...
-
Closers
In addition, ADAAG requires that low-energy doors not open to back check faster than 3 seconds and require no more than 15 Ib, which is consistent with ANSI/BHMA A156.19....
-
[A] PUBLIC WAY
A street, alley or other parcel of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and...
-
11B-607.7 Bathtub enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub....
-
§ 37.131(b)(1)
during at least all normal business hours of the entity's administrative offices, as well as during times, comparable to normal business hours, on a day when the entity's offices are not open...
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
PUBLIC WAY
A street, alley or other parcel of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and...
-
502.2.1 On-street parallel parking
Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. Figure 502.2 Vehicle Parking Spaces...
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
B. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the restroom door from the pull side and pull it open without it hitting the wheelchair - this requires at least 18"...