Each transfer step shall be 8 inches (205 mm) high maximum.
Search Results "Head Height"
Commonly Searched Documents
-
1008.3.2.2 Height
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in 308.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
T304.2 Height
Operable parts shall be located 24 inches (610 mm) minimum and 48 inches (1220 mm) maximum above the floor of non-rail vehicles.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
4.27.3* Height
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.25.3 HEIGHT
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6. Clothes rods shall be a maximum of 54 in (1370 mm) from the floor (see Fig....
- Defining and Delivering Disability-Competent Care - The Lived Experience Of Disability
-
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impacts Performance Phase 2: Final Report
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impact Performance Phase 2: Final Report REPORT PREPARED FOR: U.S ACCESS BOARD, WASHINGTON,...
-
B. Question 2: Section 904.4.1 and Clear Counter Space
Defendants have satisfied 904.4.1’s length requirement if their transaction counter, as built, equals or exceeds 36 inches in length. An entity does not violate the length...
-
Two Step Transfers Attainable Heights
Maximum attainable height difference in two step transfer percentiles (in inches) Percentiles Protocol 5th...
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
As a standard , we believe the increased access goal is well met by having a 19 inch minimum height and transfer height adjustability....
- Zurn Z5560 Commercial EcoVantage Elongated Toilet ADA Height
-
California Department of Managed Health Care - Physical Access to Health Care Fact Sheet
If You Use a Wheelchair or Have a Hard Time Walking
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
- Grainger Tough Guy Stainless Steel Sanitary Napkin Receptacle, 11" Height
- Caroma® USA Somerton Smart 270 Easy Height Elongated Toilet
-
T402.8.1 Deployment to Roadways or to Curb Height Boarding and Alighting Areas
The running slope of ramps and bridgeplates used for deployment to the roadway or to curb-height boarding and alighting areas shall be 1:6 maximum, as measured to ground level with the non-rail...