Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
Search Results "Door Height"
-
11B-404.3.6 Break out opening
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
4.1.2 Surface Design of Examination Tables and Chairs
Thus, contouring must be addressed in considering minimum height standards for accessibility of transfer surfaces (Section 5.1.4)....
- How To Use the Door Closing Speed Tool
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
Visual Notification Devices
Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired....
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
Bed Height Fact Sheet
Hotels need to adopt the recommended bed height range so individuals can safely transfer to and from the bed....
-
§ 38.113(d)(2) Exception
New cars operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
Parallel Grab Bars
With respect to the lower grab bar at bathtubs, the specified mounting height has been changed to a range of 8 inches minimum to 10 inches maximum above the rim of the bathtub....
-
Handrails
...are there handrails on both sides of the stair at a uniform height of 34"-38" above the front edge of the step?...
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
- Mockett TLRAL27 Roma Series Adjustable Table Leg
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
- Access Board: Doors in a Series
- Diversified Woodcrafts 9010 ARM Lab Table Accessory
-
§ 38.153 Doors, steps and thresholds
[56 FR 45756, Sept. 6, 1991, as amended at 63 FR 51698, 51702, Sept. 28, 1998]
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
- Panda S.66 Solid Wood Folding Door System
- Panda S.51 All Aluminum Folding Door System