The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination.
Search Results "Door Height"
Commonly Searched Documents
-
T503.4 Steps at Other Doorways
-
SECTION 1004 EXIT ACCESS
SECTION 1004 EXIT ACCESS
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on. If the...
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered...
-
§ 38.73 Doorways
[See subsections ...]
-
§ 38.53 Doorways
[See subsections ...]
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
4.9.2 Treads and Risers
On any given flight of stairs, all steps shall have uniform riser heights and uniform tread widths....
-
1. Clear Width
Do bathroom doors in accessible guestrooms allow at least 32" of clear passage width to accommodate persons who use wheelchairs, walkers and other mobility aids?...
- Panda S.81 All Aluminum Multi-Slide Door System Corner Detail
- Panda S.11 Lift & Slide Wood Clad Radius Pocket Door System
- Panda TS.83 Thermally Broken Multi-Slide Door System Corner Detail
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
-
Handles, Pulls, and Knobs
Knobs that require a full hand grip and turning, including round door knobs and shower controls, do not comply because they require twisting of the wrist....
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4....
-
Study Objectives
Floor space needed for level, highest and lowest height transfers to seats without handhelds, with grab-bars, and with grab bars and a backrest d....
- Mockett TLEL3 Electrically Driven Adjustable Table Legs
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....