(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
Search Results "Continuous Width"
Commonly Searched Documents
-
§ 38.39(b)
-
§ 38.125(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
Emergency Egress
assistance accessible egress routes that coincide with other exit routes to avoid forcing a person using a wheelchair to travel against the general flow increased aisle widths...
-
Accessible Means of Egress
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
12101(a)(2)
historically, society has tended to isolate and segregate individuals with disabilities, and, despite some improvements, such forms of discrimination against individuals with disabilities continue...
-
Are transportation operators required to retrofit their vehicles to accommodate larger and heavier wheelchairs?
No. 49 CFR Part 38 continues to require that lifts have a minimum design load of 600 pounds and the lift platform accommodates a wheelchair measuring 30 inches by 48 inches....
-
Are transportation operators required to retrofit their vehicles to accommodate larger and heavier wheelchairs?
No. 49 CFR Part 38 continues to require that lifts have a minimum design load of 600 pounds and the lift platform accommodates a wheelchair measuring 30 inches by 48 inches....
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
-
POWER-ASSISTED DOOR
[DSA-AC] A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied...
-
POWER-ASSISTED DOOR
[DSA-AC] A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied...
- Gamco Recessed Coverall Combination Towel Dispenser and Waste Receptacle - TW-9
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
Polypavement
Upon drying up, the surface remained cracked and was heaving along the full width of the trail....
-
Current illegal use of drugs
Current illegal use of drugs means illegal use of drugs that occurred recently enough to justify a reasonable belief that a person's drug use is current or that continuing use is a real...
-
Current illegal use of drugs
Current illegal use of drugs means illegal use of drugs that occurred recently enough to justify a reasonable belief that a person's drug use is current or that continuing use is a real...
-
Current illegal use of drugs
Current illegal use of drugs means illegal use of drugs that occurred recently enough to justify a reasonable belief that a person's drug use is current or that continuing use is a real...
-
Current illegal use of drugs
Current illegal use of drugs means illegal use of drugs that occurred recently enough to justify a reasonable belief that a person's drug use is current or that continuing use is a real...
-
Clear Floor Space: Minimum Clear Floor Space Required - Manual, Power & Scooter
The clear floor area width dimension also informs the minimum clearance width for successful passage through corridors, doorways, and wheelchair ramps....
-
M301.2.2 Transfer Surface Size
When the transfer surface is located as described above in “A”, the width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum...
- SoloRider: Accessible Golf Cart Operational Video
-
T402.5 Surfaces
Ramp and bridgeplate surface material shall comply with T302 and extend across the full width and length of the ramp or bridgeplate....
-
11B-705.1.2.5 Blended transitions
Detectable warnings at blended transitions shall be 36 inches (914 mm) in width....