Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
Search Results "Compliance"
Commonly Searched Documents
-
11B-1008.2.6 Ground surfaces
-
11B-404.3.6 Break out opening
Exception: Where manual swinging doors and gates comply with Section 11B-404.2 and serve the same means of egress compliance with Section 11B-404.3.6 shall not be required....
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
ETA Editor's Note California Building Code Chapter 3 - Use and Occupancy Classification, is not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and has...
-
CHAPTER 1 SCOPE AND ADMINISTRATION
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 1 that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
1.1.4 Appendices
Provisions contained in the appendices of this code shall not apply unless specifically adopted by a state agency or adopted by a local enforcing agency in compliance with Health and Safety...
-
CHAPTER 31 SPECIAL CONSTRUCTION
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 31 that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
CHAPTER 16 STRUCTURAL DESIGN
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 16 that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 33 that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
ETA Editor's Note California Building Code Chapter 3, Use and Occupancy Classification, is not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and has...
-
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 33 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 30 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31 SPECIAL CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 16 STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31B [DPH] PUBLIC POOLS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31B that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 10 MEANS OF EGRESS
ETA Editor's Note Sections from California Building Code Chapter 10 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 16A STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16A that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 2 DEFINITIONS
ETA Editor's Note Sections from California Building Code Chapter 2 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-1008.2.6 Ground surfaces
Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
-
11B-404.3.6 Break out opening
Exception: Where manual swinging doors and gates comply with Section 11B-404.2 and serve the same means of egress compliance with Section 11B-404.3.6 shall not be required....
-
11B-703.1.1.2 Inspection
The inspection shall include, but not be limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance...
-
CHAPTER 1 SCOPE AND ADMINISTRATION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 1 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
TECHNICALLY INFEASIBLE
essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces or features that are in full and strict compliance...