Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
Search Results "Warning Curb"
Commonly Searched Documents
-
608.1 General
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
11B-215.1 General
Facility alarm systems (other than fire alarm systems) such as those used for tornado warnings and other emergencies are not required to comply with the technical criteria for alarms in...
-
Accessible Parking
In order for an accessible parking space to be usable, all elements of the space must be free of obstructions: the vehicle space, the access aisle, the curb ramp, and the route that...
-
4.7.11 ISLANDS
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long in the part of the island intersected...
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
Alerts
, these can include: Extreme weather, and other threatening emergencies in your area Wireless Emergency Alerts (WEA) from the National Weather Service include: tsunami warnings...
-
203.6 Single Occupant Structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
R302.3 Continuous Width
Except as provided in R302.3.1 and R302.3.2, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
R308.1.1.1 Dimensions
Boarding and alighting areas shall provide a clear length of 2.4 m (8.0 ft) minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 1.5 m (5.0 ft) minimum...
-
502.2.1 On-street parallel parking
Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. Figure 502.2 Vehicle Parking Spaces...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Temporary Solutions For Emergency Sheltering - Ramps
Problem: The accessible route crosses a curb but no curb ramp is provided. Suggestion: Install a portable ramp with a slope no steeper than 1:12 with edge protection....
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
§ 36.403(e)(2)
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
Sec.36.403(e)(2)
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
11B-203.6 Single occupant structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
-
2. Redressability
With regard to curb ramps, Kirola seeks an injunction requiring the City to, within ten years of judgment, construct an accessible curb ramp at every existing or potential curb ramp location...
-
ADA Requirements
For example, the Standards include requirements for braille and raised letter signs and cane-detectable warnings of safety hazards for persons who are blind or have low vision....
-
1131B.2, Item 1
If there are curbs between the access aisle and the vehicle pull-up space, a curb ramp shall be provided....
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...