All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
Search Results "Site Arrival Point"
-
11B-104.1.1 Construction and manufacturing tolerances
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
711.3.4 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible items beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the wall is maintained...
-
1008.4.5 Transfer Supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
M305.2.2 Structural Strength
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
DEPARTMENT OF TRANSPORTATION DISABILITY LAW GUIDANCE: Origin-to-Destination Service
of origin to their point of destination....
-
Side reach (Section-by-Section Analysis)
, or exterior site must be placed at an accessible height....
-
Side reach (Section-by-Section Analysis)
, or exterior site must be placed at an accessible height....
-
Summary of Major Provisions
Where group sites are developed for emergency transportable housing units, the final rule requires at least 10 percent of the unit pads at each group site to be designed and constructed...
-
Viewing Areas
Because overlooks and viewing areas are destination points, they must be accessible so all visitors can enjoy the viewing opportunities....
-
PROVIDING ACCESSIBLE POLLING PLACES
For example, the only suitable polling site in a precinct might be an inaccessible building. ...
-
Accessible Means of Egress
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
106.5.2 Accessible Means of Egress
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
5.1.4 Transfer Surface Height Measurement
The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of bolsters....
-
502.3.13 Modification of Focus Cursor
Focus, text insertion point, and selection attributes that can be set by the user shall be capable of being set programmatically, including through the use of assistive technology....
-
603.3 Accommodation of Communication Needs
Support services shall be provided directly to the user or through a referral to a point of contact....
-
711.4.5 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible materials beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the horizontal...
-
13. Places of assembly
Places of assembly 4.31 If provided in the facility or at the site....