Clarification was requested on which types of doors this is intended to cover and whether it applies to shower doors. Response....
Search Results "Shower Door"
-
Doorways
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
6.3(1)
(1) Each bedroom shall have a door that complies with 4.13....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
- BEA Inc. LZR-Microscan Swinging Door Sensor
- American Specialties Retractable Shower Seat 170
- Besam SL500 A01 sliding door with outstanding performance
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
- Visitability
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....
-
11B-610.3.1 Rectangular seats
11B-610.3.1 Rectangular seats. The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The side...
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....