- Access Board: Signs
-
E. M305 Supports
M305 provides the technical requirements for supports on medical diagnostic equipment. There were multiple significant changes made to the transfer supports section, including the...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
-
§ 38.83(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
- Registry of Interpreters for the Deaf, Inc.
-
Golf Facilities: ADA Standard Section 206.2.15
Section 206.2.15 covers scoping requirements in the most current ADA Standards for accessible routes to golf facilities
-
Utility and Sewage Hookups [1011.2, 1011.3, and 1011.6]
At utility hookups, such as electrical service, water, cable or Internet connections, in camping units with mobility features and at sewage hookups in dump stations, a minimum of 30...
-
11B-206.2.15 Golf facilities
golf car rental areas; bag drop areas; course weather shelters complying with Section 11B-238.2.3; course toilet rooms; and practice putting greens, practice teeing grounds, and teeing stations...
-
11B-812.10.4 Location
EV chargers shall be adjacent to, and within the projected width of, the vehicle space being served. Exceptions: EV chargers serving more than one EVCS shall be adjacent to,...
-
F. Chapter 5: Doorways, Circulation Paths, and Fare Collection Devices
Chapter 5 in the 2016 Non-Rail Vehicle Guidelines contains the technical requirements for doorways, illumination at doorways and boarding and alighting areas, passenger access routes, and...
-
407.2.3.1 Floor Designation
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided...
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both...
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both tactile characters...
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both tactile characters...
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both...
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both...
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or...
-
At what types of property/sites must the ADA requirements be met?
RESPONSE: EVCS installed at public buildings, public accommodations, commercial facilities and public housing are required to comply with the accessibility requirements in CBC...
-
What types of exemptions or exceptions exist?
RESPONSE: EVCS installed at public buildings, public accommodations, commercial facilities and public housing are required to comply with the accessibility requirements in CBC...
-
Are the ADA spaces ADA-only? Vans only in Van accessible spaces?
RESPONSE: Standard accessible and van accessible EVCS vehicle spaces which display the International Symbol of Accessibility (ISA), sometimes referred to as the wheelchair symbol,...
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
11B-812.5.4 Arrangement
Vehicle spaces and access aisles shall be designed so that persons using them are not required to travel behind vehicle spaces or parking spaces other than the vehicle space in which...