Search Results "Rail Station Sign"
-
T201 General
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
ACCESSIBLE ROUTE & PATH OF TRAVEL QUESTIONS:
[See subsections ...]
-
There does not seem to be a distinction between different EVCS standards (Level 1, Level 2, DC CHAdeMO, DC CCS, and Tesla). Does the schedule defined in Table 11B-228.3.2.1 make a distinction between the different types of EVSE standards or are that all considered to equivalently be an EVCS?
RESPONSE: The CBC Chapter 11B accessibility requirements for EVCS do not distinguish between the different EVCS standards like those listed. However, building officials may view...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10 Electric vehicle chargers
[See subsections ...]
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
11B-812.10 Electric vehicle chargers
[See subsections ...]
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
- Rehabilitation Engineering Research Center on Accessible Public Transportation
- Access Board: Sign Scoping
-
§ 38.95(b)(13) Handrails
The handrails shall be capable of withstanding a force of 100 pounds concentrated at any point on the handrail without permanent deformation of the rail or its supporting structure....
-
T604 Stowage
[See subsections ...]
-
T704.3 Automated Announcement Systems
Automated systems for stop announcements and route identification announcements shall comply with T704.3.
-
T211 Wheelchair Securement Systems
[See subsections ...]
-
T211 Wheelchair Securement Systems
Wheelchair securement systems complying with the technical requirements in T603 must be provided at each wheelchair space. The Access Board received several comments on the proposed...
-
§ 38.97(a)
(a) Where provided, handrails or stanchions within the passenger compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility...
-
§ 38.113(d)(3) Exception
(3) Exception. Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d) (1) or (2), platform or portable lifts complying with...
-
§ 38.111(a)(2)
(2) Single-level dining and lounge cars shall have at least one connecting doorway complying with §38.113(a)(2) of this part connected to a car accessible to persons using...
-
§ 38.95(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off.