ADAAG provisions for stairs include the requirement that all steps have uniform riser heights and uniform tread widths of not less than 11 inches, measured from riser to riser....
Search Results "Mitigating Measures"
-
Accessible Pool Stairs
-
§104.44(c) Course examinations
student's achievement in the course, rather than reflecting the student's impaired sensory, manual, or speaking skills (except where such skills are the factors that the test purports to measure...
-
7(2)(b)(vii)
If the shower stall is the only bathing facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, and measures a nominal 36 x 36, the shower...
-
2 Method
The two main dependent measures were: Whether the detectable warnings could be seen from distances between 2.44 m (8ft) and 7.92 m (26 ft)....
-
903.4 Back Support
Back support shall be 2 1/2 inches (64 mm) maximum from the rear edge of the seat measured horizontally. ...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
§ 38.125(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
§ 38.83(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
-
§ 38.95(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Final Regulatory Flexibility Analysis
satisfied their readily achievable barrier removal obligations for a given year if, during that tax year, they had spent at least 1 percent of their respective gross revenues undertaking measures...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Privacy: ADA Standard Section 707.4
., a covered entity does not have to take measures that would result in a fundamental alteration of its program or would cause undue burdens, provide adequate protection to operators of...
-
Evaluating Physical and Mental Qualification Standards Under the ADA
Standards that measure a physical or mental ability needed to perform a job....
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
§ 36.303(c)(1)(ii)
should consult with individuals with disabilities whenever possible to determine what type of auxiliary aid is needed to ensure effective communication, but the ultimate decision as to what measures...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm)....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
E102.8 Telecommunications Industry Association (TIA)
TIA 1083 defines measurement procedures and performance requirements for the handset generated audio band magnetic noise of wire line telephones, including digital cordless telephones....
-
III-9.8000 Certification and barrier removal in existing facilities
The Department will measure equivalency against subpart D of the title III rule, New Construction and Alterations....
-
Can handrails or other elements overlap door maneuvering clearances?
The door maneuvering clearance must be measured from the leading edge of such elements so that the full clearance is free of any obstruction....
-
4 - Best practices for construction observation
Even though the final responsibility rests with the contractor, the architect, or other design professional should be observing construction and requiring the contractor to use the measurement...