When used for boarding and alighting, ramps and bridgeplates shall be firmly attached to the non-rail vehicle to prevent displacement....
Search Results "Curb Ramp Bottom Landing"
Commonly Searched Documents
-
T402.3 Installation and Operation
-
406.3 Sides of Curb Ramps
406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps...
-
C1-6. Accessible Route Slope
If the slope of part of the accessible route is greater than 1:20, does this part meet the following requirements for an accessible ramp? Yes _____ No _____...
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
T402.10 Visual Contrast
The perimeter of the walking surface on ramps and bridgeplates shall be marked by a stripe....
-
Recreational Boating Facilities: ADA Standard Section 235
Section 235 covers scoping requirements in the current ADA Standards for recreational boating facilities.
-
General: ADA Standard Section 235.1
Section 235 of the ADA Standards covers information in the current ADA Standards on scoping requirements for recreational boating facilities.
-
Cross Section: ADA Standard Section 505.7
Section 505.7 covers the current ADA Standards for the cross section of handrail gripping surfaces.
-
11B-235.1 General
Recreational boating facilities shall comply with Section 11B-235.
-
11B-235 Recreational boating facilities
[See subsections ...]
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2.
-
Overview
A second applies to wave pools, lazy rivers, sand bottom pools, and other pools that have only one point of entry....
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
-
1015.3 Height
On ramps and ramped aisles, from the ramp surface at the guard....
-
406.3 Sides of Curb Ramps
Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps...
-
1015.3 Height
On ramps and ramped aisles, from the ramp surface at the guard....
-
3. Exception to Ramp Running Slope
A ramp in the built environment to which this exception applies may use a 1:2 grade slope on a short rise ramp....
-
§ 38.125(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel. Where in-car signals are...
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel. Where in-car signals are...
-
407.2.2.1 Visible and Audible Signals
407.2.2.1 Visible and Audible Signals. A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of...
-
Americans with Disabilities Act (ADA) Standards for Transportation Facilities
based on the Board's ADA Accessibility Guidelines (ADAAG) but include additional requirements concerning: Location of Accessible Routes (206.3) Detectable Warnings on Curb...
-
§ 38.159(c)(1) Design load
Ramps 30 inches (760 mm) or longer shall support a load of 600 pounds (2665 N), placed at the centroid of the ramp distributed over an area of 26 inches by 26 inches (660 mm by 660 mm),...