Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel approach to...
Search Results "Bathtub Clearance"
Commonly Searched Documents
-
807.2.3 Beds
-
B. Slopes
B. Slopes - Examine each of the interior routes described above: ...excluding accessible ramps, do the corridors have running slopes (i.e.: in the direction of travel) not more...
-
J1
J1. If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking...
-
807.2.3 Beds
807.2.3 Beds. Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
11B-604.7 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
Dispensers [4.16.6]
Dispensers [4.16.6] Toilet paper dispensers should be located below the side grab bar so that they do not obstruct use of this bar. For this reason, large dispensers that do not...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
§ 38.159(d)(2) Location and size
(2) Location and size. The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
in base (proposed M301.4.1) or clearance around base (proposed M301.4.2) technical requirements....
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
The vertical clearance at doorways with lifts, ramps or bridgeplates shall comply with T502.2....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
-
Guest Bathrooms
Portable shower benches must also meet the length, width, and depth requirements of a wall-hung bench. 610.2 Bathtub Seats....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
Where bedrooms are less than 70 square feet, the section specifies that the furniture supplied with the unit cannot overlap the accessible route, maneuvering clearances required at doors...
-
11B-809.9.2 Clear width
U-shaped kitchens, designed with parallel approach at a sink, range, cooktop or other fixtures and appliances located at the base of the U without knee and toe clearance, shall provide a...
-
M301.4.1 Clearance in Base
[See subsections ...]
-
§ 38.23(b)(13) Handrails
Handrails shall be placed to provide a minimum 11⁄2 inches knuckle clearance from the nearest adjacent surface....
-
§ 38.125(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....