Mountain bikes, motorcycles, and small ATVs may be able to maneuver around obstacles and gates. In these cases, signs should be considered for additional travel management. All signs...
Search Results "Tactile Exit Signage"
-
Signs
-
703.5 Visual Characters
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
1010.1.9.8.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
A4.30.7 Symbols of Accessibility for Different Types of Listening Systems
Paragraph 4 of this section requires signage indicating the availability of an assistive listening system....
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
They must provide direct access to an exit stairway (or to an elevator equipped with standby power). Horizontal exits can substitute for areas of refuge....
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
-
11B-502.6 Identification
SECTION TITLE NOTES 11B-502.6 Identification Amends current regulations to require the...
-
11B-216.8.1 Geometric symbols
Geometric symbols complying with Section 11B-703.7.2.6 shall be provided at entrances to toilet and bathing rooms. Exceptions: 1. Geometric symbols shall not be required at...
-
11B-216.8.1 Geometric symbols
Geometric symbols complying with Section 11B-703.7.2.6 shall be provided at entrances to toilet and bathing rooms. Exceptions: Geometric symbols shall not be required at...
-
216.4.3 Directional Signs
Signs required by section 1003.2.13.6 of the International Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by...
- Access Board: International Symbol of Accessibility (ISA) Technical Requirements
- Inclusion Solutions Voter Parking Sign
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
-
1010.1.9.7 Delayed egress locks
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
-
1009.3 Stairways
Exit access stairways that connect levels in the same story are not permitted as part an accessible means of egress....
-
4.1.3(19)(b)
Signage complying with applicable provisions of 4.30 shall be installed to notify patrons of the availability of a listening system....
-
11B-216.6 Entrances
The signage program should be designed to consider differing uses of a facility which occur at different times of the day....
-
216 Signs
The sign shall be illuminated when exit sign illumination is required....
-
§27.71(k)(6)(ii) Alphabetic keys.
The “F” and “J” keys must be tactilely distinct from the other keys....
-
§ 27.71(k)(6)(ii) Alphabetic keys
The “F” and “J” keys must be tactilely distinct from the other keys....
-
1009.3 Stairways
[DSA·AC & HCD 1.AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
Can you provide recommended signage for ADA accessible spaces?
RESPONSE: Required identification signs for accessible EVCS vehicle spaces are indicated in CBC Chapter 11B Section 11B-812.8 and required vehicle space surface markings are...
-
Routes and Destinations: ADA Standard Section 810.6.2
At least one tactile sign identifying the specific station and complying with 703.2 shall be provided on each platform or boarding area....