Raised Work Areas (§203.9) Employee work areas under 300 s.f. that are elevated at least 7” as an essential functional condition of the space (excluding raised courtroom...
Search Results "Tactile Exit Signage"
-
Raised Work Areas (§203.9)
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
Determine Your Evacuation Options When Traveling
Do you check exit routes on the back of guest room doors and familiarize yourself with the exits (by tracking the escape route, noting the number of doors between your room and the emergency...
-
§382.57(c)(6) Input
(6) Input. Input devices must comply with paragraphs (c)(6)(i) through (iv) of this section.
-
§ 382.57(c)(6) Input
(6) Input. Input devices must comply with paragraphs (c)(6)(i) through (iv) of this section.
-
11B-703.7.2.5 Cleaner Air Symbol
Rooms, facilities and paths of travel that are accessible to and usable by people who are adversely impacted by airborne chemicals or particulate(s) and/or the use of electrical...
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ...
-
Signs
Signs. Section 216.10 of the 2010 Standards requires each covered assembly area to provide signs at each auditorium to inform patrons that assistive listening systems are available....
-
11B-216.13.2 Removal of Cleaner Air Symbol
If the path of travel, room and/or facility identified by the Cleaner Air Symbol should temporarily or permanently cease to meet the minimum conditions of use identified in Section...
-
11B-216.13.1 Use of Cleaner Air Symbol
Use of the Cleaner Air Symbol is voluntary. Where publicly funded facilities or any facilities leased or rented by the State of California, not including concessionaires, comply with...
-
11B-216.13 Cleaner Air Symbol
[See subsections ...]
-
11B-703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with Sections 11B-703.3 and 11B-703.4. Advisory 11B-703.3 Braille. Contracted Braille uses special characters called...
-
703.2 Raised Characters
Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4. Advisory 703.2...
-
703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. Figure 703.6.1 Pictogram Field
-
703.7.2.4 Assistive Listening Systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4.
-
R211.1 General
R211.1 General. Signs shall comply with R211. Where audible sign systems and other technologies are used to provide information equivalent to the information contained on pedestrian...
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
T702.7 Line Spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
T702.3 Character Proportions
Characters shall use fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
T702.2 Character Style
Characters shall be displayed in sans serif fonts and shall not use italic, oblique, script, highly decorative, or other unusual forms.
-
T702.4 Character Height
Character height shall comply with Table T702.4. Character height shall be based on the uppercase letter “I”. Table T702.4—Character Height Sign...
-
T215.2.4 Destination and Route Signs
Where destination or route signs are provided on the exterior of non-rail vehicles, such signs shall be located at a minimum on the front and boarding sides of the vehicle. The signs...