Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat...
Search Results "Seat Location"
-
11B-604.9 Water closets and toilet compartments for children's use
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
11B-608.5.3 Alternate roll-in type shower compartments
and 27 inches (686 mm) maximum from the seat wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
Guest Bathrooms
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
§ 36.302(f)(1)(ii) Ticket sales
event or series of events shall modify its policies, practices, or procedures to ensure that individuals with disabilities have an equal opportunity to purchase tickets for accessible seating...
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
382.81 For which passengers must carriers make seating accommodations?
382.81 For which passengers must carriers make seating accommodations? ETA Editor's Note This section has no content in the original document....
-
Associated
Dispensers associated with the use of a water closet and allowed to overlap the water closet clearance include seat cover, feminine hygiene product, disposal bag, and toilet paper dispensers...
- Figure 703.4.1 Height of Tactile Character Above Finish Floor or Ground – Drawing from the U.S. Access Board
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs....
- Delta Toilet Installation Video
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
5.2.2.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
A5.1 General
Dining counters (where there is no service) are typically found in small carry-out restaurants, bakeries, or coffee shops and may only be a narrow eating surface attached to a wall....
-
5.3.3 Transfer Sides Recommendations for M302
The provisions result in the transfer surface being located at a corner of the equipment and the two transfer sides adjoining at the edges of the equipment....
-
5.2.2.1 Transfer Surface Width
The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
T605 Seat Belts and Shoulder Belts
[See subsections ...]