5 through 8 Ages 9 through 12 Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat...
Search Results "Seat Location"
-
11B-604.9 Water closets and toilet compartments for children's use
-
11B-604.9 Water closets and toilet compartments for children's use
Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat...
-
11B-608.5.3 Alternate roll-in type shower compartments
and 27 inches (686 mm) maximum from the seat wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
- Delta Toilet Installation Video
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
Guest Bathrooms
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
§ 36.302(f)(1)(ii) Ticket sales
event or series of events shall modify its policies, practices, or procedures to ensure that individuals with disabilities have an equal opportunity to purchase tickets for accessible seating...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
- Whitehall Mfg. WH2125A On-Floor Bariatric Stainless Steel Toilet
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
- Figure 802.2.1.1 Lines of Sight Over the Heads of Seated Spectators – Drawing from the U.S. Access Board
- Figure 802.2.1.2 Lines of Sight Between the Heads of Seated Spectators – Drawing from the U.S. Access Board
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
11B-221.2.4 Temporary structures
Wheelchair spaces shall not be located on, or be obstructed by, temporary platforms or other movable structures....
-
382.81 For which passengers must carriers make seating accommodations?
382.81 For which passengers must carriers make seating accommodations? ETA Editor's Note This section has no content in the original document....
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs....
-
A5.1 General
Dining counters (where there is no service) are typically found in small carry-out restaurants, bakeries, or coffee shops and may only be a narrow eating surface attached to a wall....
-
5.2.2.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...