Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist....
Search Results "Pedestrian Traffic Control Button"
Commonly Searched Documents
-
1134A.8, Item 7
-
27.1 Q. Do the Guidelines set any requirements for the type or location of bathtub controls?
In that case, while the type of control is not specified, the control must be located as shown in Figure 8 of the Guidelines. ...
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
M307 Operable Parts (Section-by-Section Analysis)
For example, equipment used for an auditory examination may require the patient to press a button when sounds are heard....
-
309.3 Height
309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.
-
M307.1 General
Operable parts for patient use shall comply with M307.
-
M307.1 General (Section-by-Section Analysis)
This is an introductory section.
-
M307.3 Operation (Section-by-Section Analysis)
The MDE NPRM proposed to require operable parts to be operable with one hand and not require tight grasping, pinching, or twisting of the wrist. There were no public comments on this...
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
R403.3 Height
R403.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in R406.
-
T304.2 Height
Operable parts shall be located 24 inches (610 mm) minimum and 48 inches (1220 mm) maximum above the floor of non-rail vehicles.
-
R403.2 Clear Space
R403.2 Clear Space. A clear space complying with R404 shall be provided at operable parts.
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4. Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches...
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.
-
M307.1 General
Operable parts for patient use shall comply with M307.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.