interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within guestrooms allow at least 32" clear...
Search Results "Clear Opening"
-
C. Doors
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
- Sargent 281 Series Cast Iron Door Closer
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
Doors [9.2.2(3), 9.4]
Because of the social interaction and visitation that often occurs in lodging facilities, an accessible door clear opening width (32 inches minimum) is required to and within all sleeping...
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
B. Accessible Route
Is there a route to these 5% accessible fixed tables that allows at least 36" clear width and has no abrupt vertical level changes greater than 1/4"?...
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum. Exceptions: 1....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1.
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1.
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
Accessible Ground Surfaces
Accessible Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, and maneuvering spaces, must comply with the American Society for Testing and Materials...
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum. Exceptions: 1. ...
-
4.3.5 Turning clearance
A 180-degree turn is more appropriate as a basis for defining a minimum space bounded only on two sides and the individual has an open space to use along the axis of the turn....