Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
Search Results "Wheelchair Passing Space"
Commonly Searched Documents
-
11B-1008.2.3 Water play components
-
Appendix 1 – Details of Research Methodologies
Appendix 1 – Details of Research Methodologies
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
Both designs have the potential to reduce the number of available wheelchair seating spaces below the level required. ...
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
- Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment – Drawing from the U.S. Access Board
-
Bias Toward Wheelchair Users
Two commenters stated that the proposed guidelines were biased toward wheelchair users, and that the Department has erroneously assumed that the elderly and the physically disabled have...
-
Limited Access Spaces (§203.4)
Limited Access Spaces (§203.4) Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways Examples: lighting/ equipment catwalks at stages and performing...
-
1.0 Background
1.0 Background The standards used to ensure accessibility for people who use wheeled mobility devices like wheelchairs and scooters are based on research in anthropometry, the measurement...
-
Knee Clearance: Clearance as Measured from Distal Knee Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the distal knee point touching an obstruction....
-
R203 Machinery Spaces
R203 Machinery Spaces. Vaults, tunnels, and other spaces used by service personnel only for maintenance, repair, or monitoring are not required to comply with this document....
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the forward-most point touching the wall....
-
Knee Clearance: Clearance as Measured from Dorsal Foot Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the dorsal foot point touching an obstruction....
-
309.2 Clear Floor Space
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided....
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
Clear Deck Space
Clear Deck Space The base of the transfer platform must have a clear deck space adjacent to it that is 60 by 60 inches minimum, with a slope not steeper than 1:48 so a person using a...
-
11B-208 Parking spaces
[See subsections ...]
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
CLEAR FLOOR SPACE
[DSA-AC & HCD 1-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....