If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to transfer onto...
Search Results "Transfer Technique"
-
J. Transfer Space
- The Association of Safe Patient Handling Professionals
-
Design Criteria for the Transfer Station
A custom-built modular transfer station was designed and fabricated to meet the study goals....
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. ...
- Bradley Grab Bars 1 1/2" with Concealed Mounting 812
- Comfort Designs Comfort Care™ Grab Bars
- Murdock Manufacturing Grab Bars
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest room....
- Ella Wheelchair Transfer Tub Video
-
M301.3 Supports (Section-by-Section Analysis)
This is an introductory section. An editorial change was made to this section as a result of the change in M301.3.2, described below, to replace the word “stirrups” with the term...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
Plan 6A: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest...
-
711.4.4 Ducts and air transfer openings
Penetrations of horizontal assemblies by ducts and air transfer openings that are not required to have dampers shall comply with this section....
-
ADA Revised Requirements: Ticket Sales
The Department of Justice published revised final regulations implementing the Americans with Disabilities Act (ADA) for title II (State and local government services) and...
- Comfort Designs Tamper Proof Anti-ligature Grab Bars
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:
-
709.8 Duct and air transfer openings
Penetrations by duct and air transfer openings shall comply with Sections 711 and 715....
-
Minimum Number: ADA Standard Section 234.4.2
Section 234.4.2 covers the most current ADA scoping requirements for the minimum number of wheelchairs spaces, transfer seats or devices at existing amusement rides.
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
- Willoughby Industries WRS-BF-FA Front Mounted Recessed Shower Panel With Hand Held Flexshower Head
- 609.3 Grab Bar Vertical Clearance
- Willoughby Industries WRS-BF-FA-2HD Front Mounted Recessed Shower Panel 2 Fixed Shower Heads
- Ampetronic TalkPerfect Duplex Intercom, Speech Transfer System