Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
Search Results "Passenger Coach Car"
Commonly Searched Documents
-
409.3.1 Power Operation
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel....
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel....
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel....
-
§382.101 What other boarding and deplaning assistance must carriers provide?
assistance is not required to be provided under this subpart, you must, as a carrier, provide or ensure the provision of boarding and deplaning assistance by any available means to which the passenger...
-
Wheelchairs Unable to be Stowed in the Cabin as Carry-on
Cabin as Carry-on When a folding, collapsible, or break-down wheelchair cannot be stowed in the cabin as carry-on baggage, carriers must ensure the timely checking and return of the passenger’s...
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The audio output shall provide verbal instruction for the user to enter a destination floor. The selected destination floor shall be confirmed by verbal announcement and on the...
-
11B-502.3.3 Marking
Access aisles shall be marked with a blue painted borderline around their perimeter. The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches...
-
4.10.6* Door Protective and Reopening Device
They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person....
-
§382.19(c)
(c) You may refuse to provide transportation to any passenger on the basis of safety, as provided in 49 U.S.C. 44902 or 14 CFR 121.533, or to any passenger whose carriage would violate FAA...
- DBTAC: Accessible Parking With Robert David Hall
-
Four Specific Situations in which a Seating Accommodation Must be Provided
a row with a movable armrest if one exists [Sec. 382.38(a)(1)]; If the passenger (i) is a passenger who is traveling with an attendant who will be performing functions during the...
-
407.4.7.2 Keypads
Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot. The dot...
-
11B-407.4.7.2 Keypads
Keypads shall be identified by characters complying with Section 11B-703.5 _|Signs; Visual Characters|_ and shall be centered on the corresponding keypad button. The number five key...
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.