Search Results "Board"
Filters
Commonly Searched Documents
- Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats – Drawing from the U.S. Access Board
- Figure 802.2.1.1 Lines of Sight Over the Heads of Seated Spectators – Drawing from the U.S. Access Board
- Figure 802.2.2.2 Lines of Sight Between the Heads of Standing Spectators – Drawing from the U.S. Access Board
- Figure 802.2.2.1 Lines of Sight Over the Heads of Standing Spectators – Drawing from the U.S. Access Board
- Figure 802.2.1.2 Lines of Sight Between the Heads of Seated Spectators – Drawing from the U.S. Access Board
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- Figure 604.5.2 Rear Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- Figure 409.4.6.2 Location of Private Residence Elevator Control Panel – Drawing from the U.S. Access Board
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
- Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance – Drawing from the U.S. Access Board
- Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers – Drawing from the U.S. Access Board
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 404.2.4.3(c) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 404.2.4.3(b) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 406.2 Counter Slope of Surface Adjacent to Curb Ramps – Drawing from the U.S. Access Board
- Figure 609.2.2 Grab Bar Non-Circular Cross Section – Drawing from the U.S. Access Board
- Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board
-
Dispersion Requirements
In the proposed rule, the Board posed several questions concerning the requirements for the dispersion of wheelchair spaces (which were located in section 802.6)....
-
Fact Sheet: Highlights of the Final Rule to Amend the Department of Justice's Regulation Implementing Title III of the ADA
Architectural and Transportation Barriers Compliance Board (Access Board)....
-
Shower Threshold
The Board retained the ½ inch threshold height since positioning for transfer to the seat of transfer showers can be aided where a close approach enables footrests to clear the threshold...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
NPRM Preamble Discussion: The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment...